(a) The requirements of this section apply to the owner or operator of a municipal solid waste landfill that co-disposes of sewage solids within the boundaries of the MSWLF.
(b) Sewage solids may not be placed in an active MSWLF if they are regulated hazardous wastes, are regulated under 18 AAC 60.020(a) , or if they contain concentrations of polychlorinated biphenyls (PCB) wastes defined in 40 C.F.R. 761.3, revised as of July 1, 1998, adopted by reference.
(c) Sewage solids may not be placed in an active MSWLF if they contain "free liquids" as defined by EPA Method 9095 (Paint Filter Liquids Test), as described in Test Methods for Evaluating Solid Waste, Physical/Chemical Methods, (SW 846), Third Edition, inlcuding Final Update III (December 1996), adopted by reference.
(d) If sewage solids are placed in a MSWLF, the owner or operator shall meet the vector reduction requirement in 40 C.F.R. 503.33(b)(11), adopted by reference in 18 AAC 60.505, or one of the
(1) Class A or Class B pathogen reduction requirements in 40 C.F.R. 503.32, adopted by reference in 18 AAC 60.505; and
(2) the vector attraction reduction requirements of 40 C.F.R. 503.33(b)(1) - (10), adopted by reference in 18 AAC 60.505.
(e) The owner or operator of a Class III MSWLF may dispose of up to 2,500 gallons of septage per day in trenches at the landfill if the owner or operator
(1) constructs and fills one septage disposal trench at a time, ensuring that the trench has at least one square foot of wetted surface for each gallon of material disposed on any day;
(2) maintains at least a four-foot separation distance between the seasonal high groundwater and the base of the trench;
(3) constructs each trench in sandy soil with a hydraulic conductivity no less than 1 x 10 4 centimeters per second and no greater than one centimeter per second;
(4) adds hydrated lime or quicklime in a dry form so that a pH of 12 is maintained in the septage for at least 30 minutes; and
(5) ensures that septage does not overflow the trench or accumulate more than four feet in depth of liquid.
History: Eff. 1/28/96, Register 137; am 10/29/98, Register 148; am 7/11/99, Register 151; am 9/7/2002, Register 163
Authority: AS 44.46.020
Editor's note: Test Methods for Evaluating Solid Waste, Physical/Chemical Methods, (SW-846), adopted by reference in 18 AAC 60.365 is available from National Technical Information Services, United States Department of Commerce, 5285 Port Royal Road, Springfield, Virginia 22161. It may also be reviewed at the department's Anchorage, Fairbanks, and Juneau offices, and is on file in the Lieutenant Governor's Office.
Note to HTML Version:
The Alaska Administrative Code was automatically converted to HTML from a plain text format. Every effort has been made to ensure its accuracy, but neither Touch N' Go Systems nor the Law Offices of James B. Gottstein can be held responsible for any possible errors. This version of the Alaska Administrative Code is current through June, 2006.
If it is critical that the precise terms of the Alaska Administrative Code be known, it is recommended that more formal sources be consulted. Recent editions of the Alaska Administrative Journal may be obtained from the Alaska Lieutenant Governor's Office on the world wide web. If any errors are found, please e-mail Touch N' Go systems at E-mail. We hope you find this information useful. Copyright 2006. Touch N' Go Systems, Inc. All Rights Reserved.
Last modified 7/05/2006